Horizontal Cooking

700 Range / Boiling Pans

The cooking pots in the 700 Series have a counterbalanced hinged lid, a stainless steel burner controlled by a safety valve, a water inlet solenoid valve, hot or cold water selector switch and a pot drainage tap. This range is available in various models to suit the requirements of each customer.

fagor-logo-industrial-commercial-catering-equipment

Models and specifications

Gas indirect heating boiling pan
Double jacket pan ( bain-marie system). Counterweighted folding lid. Indirect heating system. Safety device for the bain-marie extinguishes the burner in the event of low water level. Stainless steel burner, with safety valve and thermocouple. Filling tap and control tap for the level of the double jacket pan (bain-marie ). Over-pressure safety valve. Cold and hot water feed by electrovalve. Drainage tap. Electrical supply: 230 V – 1 + N.
Model Volume in l Power kW Gas power kW Dimensions (mm) Data sheet
MG7-10 BM MG7-10 BM 80 17,00 700x775x850 Download
Steam boiling pan
Double jacket pan. Counterweighted folding lid. 1 ‘’ inlet valve and 1 ‘’ outlet valve for the steam. Steam inlet pressure: 0.4 – 0.5 bar. Over pressure safety valve. Water feed by electrovalve. Drainage tap. Electrical supply: 230 V – 1 + N.
Model Volume in l Power kW Gas power kW Dimensions (mm) Data sheet
MV7-10 BM MV7-10 BM 80 700x775x850 Download
Electric indirect heating boiling pan
Double jacket pan ( bain-marie system). Counterweighted folding lid. Shielded heating elements in stainless steel. Pilot light for heating. Control by thermostat. Filling cock and cont rol cock for the level of the double jacket pan (bain-marie). Over pressure safety valve. Cold and hot water feed by electrovalve. Drainage tap.
Model Volume in l Power kW Gas power kW Dimensions (mm) Data sheet
ME7-10 BM ME7-10 BM 80 9,00 700x775x850 Download
Gas direct heating boiling pan
Direct heating. Counterweighted folding lid. Stainless steel burner, with safety valve and thermocouple. Cold and hot water feed by electrovalve. Drainage tap. Electrical supply: 230 V – 1 + N.
Model Volume in l Power kW Gas power kW Dimensions (mm) Data sheet
MG7-10 MG7-10 80 17,00 700x775x850 Download

Please send me information about this product